SKU: AG-333

Refrigeration and Air Conditioning Unit Tow condensers(water)and tow evaporators(water and air)

Anodized aluminium structure and panels in painted steel (epoxy paint).Main metallic elements in stainless steel.Diagram in the front panel with similar distribution to the elements in the real unit.Cooling compressor.Cables and Accessories,for normal operation.Manuals:This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance Practices Manuals.Water condenser.Water evaporator.
Air evaporator. High pressure control.Coolant accumulation tank.Cooling filter.Expansion valve.Tank of division of the cooling liquid.4 Manometers 9 Temperature sensors:
Temperature sensor, J type (compressor outlet).
Temperature sensor, J type (condenser outlet).
Temperature sensor, J type (evaporator inlet).
Temperature sensor, J type (compressor inlet).
Temperature sensor, J type (water inlet).
Temperature sensor, J type (condenser outlet/water).
Temperature sensor, J type (water evaporator outlet/water)
Temperature sensor, J type (air evaporator outlet/air).
Temperature sensor, J type (room air).
Flow meters.Wattmeter.Enthalpy diagram of the refrigerant R134a.Electronic Console:Metallic box.Temperature sensors connections.Selector for temperature sensors.Digital display for temperature sensors.High pressure control connection.Fan speed selector.Wattmeter display.Compressor ON/OFF switch.Electronic Console ON/OFF switch.
This unit is available as computer controlled 

1.-Determination of the inlet power, heat produced and performance coefficient. Water as heat source.

2.-Determination of the inlet power, heat produced and performance coefficient. Air as heat source.

3.-Preparation of performance curves of the unit with different inlet and outlet temperatures. Water as heat source.

4.-Preparation of performance curves of the unit with different inlet and outlet temperatures. Air as heat source.

5.-Lay out of the steam compression cycle in a diagram P-H and comparison with the ideal cycle. Water as heat source.

6.-Lay out of the steam compression cycle in a diagram P-H and comparisas heat source.

7.-Preparation of the performance  curves of the unit based on the properties of the refrigerant and at different condensation and evaporation temperatures. Water as heat source.

8.-Preparation of the performance  curves of the unit based on the properties of the refrigerant and at different condensation and evaporation temperatures. Air as heat source.